FaxPress Premier WebHelp: Troubleshooting

Troubleshooting

Synchronizing the Premier Fax Board with the T1

Very infrequently, the T1 line will not synchronize properly between the FaxPress Premier Digital and the central office. This will cause issues with sending and receiving multiple page faxes. In this case, the Premier fax board can be configured to synchronize with the connected T1 line using the steps described below.

Implement the following changes very carefully. Incorrect parameter value changes may compromise fax board function. If you have any questions regarding this procedure, contact Castelle tech support.

To synchronize the Premier with your T1 line if you’re experiencing problems sending multiple page faxes, follow these steps:

1. Attach a mouse, keyboard, and monitor to the FaxPress Premier Digital. Although Remote Desktop can be used for configuring other aspects of the Premier system, it can’t be used for this.
2. Power on the Premier Digital.
3. Log into the Premier system as Administrator. The default password is castelle. Make sure castelle is all lower case.
4. Open the Services tool. (Start>Settings>Control Panel>Administrative Tools>Services)
5. Stop all Castelle services.
6. Stop the GammaLink System service.
1. Stop the Dialogic System Service.
2. Navigate to Program Folders\Intel\Dialogic System Software\Configuration Manager- DCM.
3. Right-click on Bus-0 and select Configure Device.
4. Select NETREF One FRU (User Defined) and edit its value to GDK_T1 0.
5. Click Apply.
6. Select Derive Primary Clock from (User Defined) and edit its value to NETREF_1.
7. Click Apply.
8. Select Primary Master FRU (User Defined), edit its value to GDK_T1 0.
9. Click Apply.
10. Select Using NETREF One (User Defined) and edit its value to Yes.
11. Click Apply.
12. Refer to the following table to verify all the parameter values are correct, then proceed to step 13.

Parameters

Original Value

New Value

TDM Bus Type (User Defined)

   

TDM Bus Type (Resolved)

H.100

 

Scbus Clock Rate (User Defined)

Default

 

Scbus Clock Rate (Resolved)

8 MHz

 

Media Type (User Defined)

Default

 

Media Type (Resolved)

MuLaw

 

Group One Clock Rate (User Defined)

Default

 

Group One Clock Rate (Resolved)

8 MHz

 

Group Two Clock Rate (User Defined)

Default

 

Group Two Clock Rate (Resolved)

8 MHz

 

Group Three Clock Rate (User Defined)

Default

 

Group Three Clock Rate (Resolved)

8 MHz

 

Group Four Clock Rate (User Defined)

Default

 

Group Four Clock Rate (Resolved)

8 MHz

 

Using Compatibility Clocks (User Defined)

Default

 

Using Compatibility Clocks (Resolved)

Yes

 

Primary Lines (User Defined)

Default

 

Primary Lines (Resolved)

A

 

Using Primary Master (User Defined)

Default

 

Using Primary Master (Resolved)

Yes

 

Using Secondary Master (User Defined)

Default

 

Using Secondary Master (Resolved)

No

 

Using NETREF One (User Defined)

Default

Yes

Using NETREF One (Resolved)

Not Applicable

 

Using NETREF Two (User Defined)

Default

 

Using NETREF Two (Resolved)

Not Applicable

 

Primary Master FRU (User Defined)

Default

GDK_T1 0

Primary Master FRU (Resolved)

GDK_T1 0

 

Derive Primary Clock from (User Defined)

Default

NETREF_1

Derive Primary Clock from (Resolved)

Internal Oscillator

NETREF_1

Secondary Master FRU (User Defined)

Default

 

Secondary Master FRU (Resolved)

Not Applicable

 

Derive Secondary Clock from (User Defined)

Default

 

Derive Secondary Clock from (Resolved)

Not Applicable

 

NETREF One FRU (User Defined)

Default

GDK_T1 0

NETREF One FRU (Resolved)

Not Applicable

GDK_T1 0

Derive NETREF One from (User Defined)

   

Derive NETREF One from (Resolved)

Not Applicable

 

NETREF One Clock Rate (User Defined)

Default

 

NETREF One Clock Rate (Resolved)

8 KHz

 

NETREF Two FRU (User Defined)

Default

 

NETREF Two FRU (Resolved)

Not Applicable

 

Derive NETREF Two from (User Defined)

   

Derive NETREF Two from (Resolved)

Not Applicable

 

NETREF Two Clock Rate (User Defined)

Default

 

NETREF Two Clock Rate (Resolved)

Not Applicable

 
13. Click OK to exit the TDM Bus Configuration.
14. Select the board GDK_T1 0, and click Start.
15. Click OK to exit the Configuration Manager - DCM.
16. Start the GammaLink System Service, start Castelle services.

 